Koolance infrared liquid level sensor. Total length of sensor = 29mm (1.14in). Nickel plated brass, G 1/4 BSPP threading.

  • Input: 5-12VDC
  • Output: 0V when in liquid, 3.5-10.5V in air
  • Current: 20mA max @ 12V
  • Connector: Molex 5264, 3-wire
  • Pinout: blue = output, black = ground, red = input (5-12VDC)
  • Wire length: 700mm

Liquid Coolants

Koolance's product warranty does not cover the use of 3rd-party coolants, coolant additives, or corrosion. Koolance LIQ-702 or LIQ-705 coolants are strongly recommended to help avoid issues with mixed metals or biological growth. Additionally, do not use aluminum with bare (unplated) copper or bare (unplated) brass in the same system. Do not use silver with nickel in the same system.